3.2.2 Motion Monitor Indicators
This section enables you to enter parameters for displaying the current status of the
drive. You use the two drop-down list boxes below the Display 1 and Display 2 text
boxes to select two vectors for display.
For linear motors, your vector options are as follows:
Active Current in amperes RMS
Auxiliary Position in counts
Position in counts
Position Error in counts
Velocity in counts/sec
Velocity in m/sec
Velocity Error in counts/sec
Velocity Error in m/sec
For rotating motors, your vector options are as follows:
Active Current in amperes RMS
Auxiliary Position in counts
Position in counts
Position Error in counts
Velocity in counts/sec
Velocity in RPM
Velocity Error in counts/sec
Velocity Error in RPM
The current drive status is indicated by the row of LEDs.
Elmo Composer User Manual Using the Composer
MAN-COMPUM (Ver. 1.9)
3-7